Analysis reader
Paste GC-MS results here — compound names and percentages. The tool matches them against the library, says plainly which compounds it recognises and which it does not, then opens them in the formula reader.
- Input
- a pasted GC/MS table (compound name and %)
- Output
- library matches, evaporation order, dominance by threshold, labelling
- Data
- the site’s compound library; what you paste never leaves the browser
Compound library Contact Formula reader
Paste the results
One compound per line: the name, then the percentage, separated by a space, a comma or a tab. The tool understands English names, standard names, and the synonyms in the library. You can paste whole report lines, including the peak number, retention time and retention index (RI): if an RI is present, the tool compares it with the DB-5 reference and points out compounds that may have been misidentified.
Matching results
| Line you pasted | Recognised as | % | RI · against DB-5 reference | Status |
|---|
Why this tool exists
A GC-MS report is a list: which compound, what percentage of peak area. It does not say which compounds you smell. Limonene at 65 % and citral at 2 % — on paper limonene dominates; in the nose, not necessarily.
A report on a plant sample, or on a bottle? Many tables in scientific papers come from a plant sample distilled in the laboratory in a Clevenger-type apparatus, that is, water distillation on a scale of a few tens of grams. Such a sample carries the marks of water distillation: more esters hydrolysed, water-soluble compounds held back. Compared with a steam-distilled commercial oil, the difference may come from the way it was distilled, not from a problem with the bottle.
This tool connects two things: the sheet from the laboratory, and a reading by odour threshold. Once the lab has lots, each lot will go down exactly this road — analysis in, reading out.
Method
Reading a line
Each line is split into compound name, retention index (RI) and percentage. An integer from 500 to 3500 after the name is the RI; the decimal at the end is the percentage; retention time and row numbers are ignored. Names are matched against every compound’s standard name and synonyms.
Checking by retention index
Δ = |RIreport − RIDB-5| Δ ≤ 10 match · Δ ≤ 25 slight · Δ > 25 large
Many terpenes have near-identical mass spectra, so a name on a report can be wrong without the spectrum catching it. The retention index can: the tool compares the report’s RI with the NIST median for that compound on a 5 %-phenyl (DB-5) column. If most lines are off in the same direction by more than 80 units, the report was probably run on a polar (WAX) column — the tool then says so once instead of flagging each line.
Limits
- Name and RI agreement is indirect evidence. Firm identification needs a reference standard run on the same instrument and column.
- An ordinary column does not separate enantiomers: (+)- and (−)-limonene give one peak. Without a chiral analysis the report cannot speak to natural versus synthetic origin.
- Report percentages are peak-area percentages, not weight percentages; the two are close but not equal.