muihuong.vnScent keeps what you forget. VI

Lab

Where scent is read in numbers. The tools run right in your browser and send no data anywhere, and they share one library with the rest of the site.

The Lab’s main tool

Formula reader

Build a bottle from the compound library and read it the way the nose does: what dominates by detection threshold rather than by percentage, what evaporates first, what the label must declare once it goes into a product — then compare two versions before you weigh.

Dominance
odour value = level ÷ threshold
Order
half-life estimated from boiling point
Label
EU allergens at your dilution
Compare
two versions of one bottle

Open the formula reader

More tools

Four calculations behind the tools

From a GC/MS report to the label on the bottle, each step answers one question and rests on one column of the library. The formulas below are the ones the tools actually run.

  1. 1Identification

    Which compound is this?

    Δ = |RIreport − RIDB-5| ≤ 10

    A name on a GC/MS report is checked by retention index: many terpenes share near-identical spectra, retention indices do not.

    101 of 113 compounds have a DB-5 RI

    Used in Analysis reader

  2. 2Evaporation

    What arrives first?

    t½ = 20 s × 103.4·(Ts − 140)/150

    Half-life on a blotter is estimated from boiling point and anchored to four compounds described in the site’s articles: from minutes (limonene) to about eleven hours (vanillin).

    87 measured boiling points, 26 estimated

    Used in Formula reader, Analysis reader

  3. 3Odour value

    What dominates?

    OV = C / T

    Concentration divided by detection threshold. Percent says what the bottle contains; odour value says what the nose notices first.

    54 of 113 compounds have a threshold, 53 measured in water

    Used in Formula reader, Analysis reader

  4. 4Labelling

    What must the label say?

    cprod = cform × f > 0.001 %

    The level in the finished product against the declaration threshold of Regulation (EU) 2023/1545: 0.001 % for leave-on, 0.01 % for rinse-off.

    23 compounds carry an EU allergen flag (10 from the original list, 13 added in 2023)

    Used in Formula reader, Analysis reader

Library coverage

A tool is only as accurate as the data it reads. This table is recounted every time the site is built; a gap in the library is a real gap, not filled with guesses. Recording rules and sources: Data standard.

FieldPresentOfShareNote
CAS number113113100 %one unique identifier per compound
Boiling point113113100 %87 measured; the rest estimated and marked on the compound page
DB-5 retention index10111389 %NIST median, 5 %-phenyl column
Detection threshold5411348 %published sources vary widely; each compound page notes the source
EU allergen flag2311320 %per Annex III, Regulation (EC) 1223/2009
Oils with measured composition15116890 %7 with a standard’s range only; 10 without a readable table

What the Lab does not do

It does not predict smell.
Mixtures do not add linearly: one compound masks another, some change character with concentration. The Lab computes structure, not sensation.
It does not replace a lot analysis.
Library figures are published figures for one sample. The bottle in your hand is known only through the GC/MS report for that lot.
It makes no claims about use.
No dosing, no therapeutic effects. Safe dilution levels are in the Safety section.
It sends no data anywhere.
Every calculation runs in your browser; formulas you save stay on your device.

The Lab’s library

Two memories, one question

Which bottle smells stronger?

Two 10 ml bottles. Tap the one you think is stronger.